9 --- 34
9.3 Regular Maintenance (Compressor)
Interval Work to be done See chapter
50 h after initial start Check all electrical connections for tightness
and toghten if necessary
Weekly Check the oil level 9.11
Check the filter mats for contamination 9.5
Indication by
S
I
G
M
A
C
O
N
T
O
L
Clean or change the air filter* 9.6
SIGM
A
CON
T
OL
Change the oil filter** 9.10
Change the oil separator cartridge* 9.13
1000 h Check the oil cooler and air aftercooler for con-
tamination
9.4
Clean or replace the filter mats* 9.5
2000 h or at least an-
nually
Grease the drive motor bearings* 9.7
2000 h Change the oil filter** 9.10
Proper interval varies.
See chapter 1.8
Change the oil* 9.12
6000/12000 h or after
3 years at the latest
Change the fan motor bearings* 9.7
Annually Check all electrical connections for tightness
and tighten if necessary
Have the safety relief valve checked by
authorized KAESER distributor
9.8
Every two years Change the air filter* 9.6
20000/35000 h or after
8 years at the latest
Remove motor bearing covers and/or end
shields, remove old grease from bearing cavity
and regrease bearings.*
9.7
* The maintenance period can vary depending on the cycle rate and environmental
conditions.
** Not to exceed 2000 service hours.
We urgently recommend that a record is kept of the maintenance work done (see chap-
ter 9.14).