EasyManua.ls Logo

Kamstrup flowIQ 3100 - Measurement Accuracy Standards

Kamstrup flowIQ 3100
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TECHNICAL DESCRIPTION flowIQ® 3100
10 Kamstrup A/S • Technical Description • 5512-1242_B1_GB • 05.2015
3 Type overview
Type 031-

0

Communication
Wireless M-Bus, 868 MHz, mode C1 ver. 2
46
Wireless M-Bus, 868 MHz, mode T1 OMS ver. 2
47
Supply
16 years’ battery life, C-cell
C
Meter size
Q3 [m³/h]
Connection
Length [mm]
Dynamic range
1.6
G¾B (R½)
110
100
A
2.5
G¾B (R½)
110
100
B
2.5
G1B (R¾)
190
100
C
4.0
G5/4B (R1)
260
100
G
6.3
G5/4B (R1)
260
100
H
10
G2B(R1½)
300
100
J
16
DN50
270
100
L
25
DN65
300
100
M
Meter type
Cold water meter, T30 or T50 (MID)
8
Country Code
XX
The type number of the meter cannot be changed after factory programming.
The country code can also be used for:
• Language and approval on type label
• Temperature class of flow sensor (T30 or T50)

Table of Contents

Other manuals for Kamstrup flowIQ 3100

Related product manuals