9 Data loggers
9.1 Memory
flowIQ® 3100 has a permanent memory (EEPROM), in which the values of various data loggers are saved.
Loggers are read through the optical eye.
The meter includes the following registers:
Data logging interval
Data logging depth
Logged value
Monthly logger 36 months Counter register
Daily logger 460 days Counter register
Info logger 50 events Info code, meter count and date
Please note that flowIQ® 3100 logs monthly values for 36 months. No yearly target values are logged.
The loggers are static ones. Thus, the register types cannot be changed. The same applies to the logging
intervals. When the last record has been written into the EEPROM the oldest one will be overwritten.