TECHNICAL DESCRIPTION flowIQ® 3100
12 Kamstrup A/S • Technical Description • 5512-1242_B1_GB • 05.2015
4 Configuration
Configuration
KK
LLL
MMM
N
P
R
S
T
□□
□□□
□□□
Target date
01
Average time of max. values
2 minutes (1…120 min.)
002
Customer label 2005-MMM
MMM
Leakage message limit
OFF
0
Flow continuously > 0.5% of Q3
1
Flow continuously > 1.0% of Q3
2
Flow continuously > 2.0% of Q3
3
Flow continuously > 0.25% of Q3
4
Flow continuously > 0.1% of Q3
5
Pipe burst limit
OFF
0
Flow > 5 % of Q3 for 30 minutes
1
Flow > 10 % of Q3 for 30 minutes
2
Flow > 20 % of Q3 for 30 minutes
3
Optional register in data logger
* Reccommended for ’Drive-by’ ** Reccommended for ’Fixed network
Meter reading target date (monthly)
1
Max. flow during last month
2
Monthly target volume/Min.temp.water, daily/Time weighted average temp. meter, daily
**
3
Monthly max. flow/Average temp.water,daily/Time weighted aver. temp. meter,daily
**
4
Monthly target volume / Min. water temp. monthly / Min. temp. meter,latest month
*
5
Monthly target volume/Min. water temp., monthly/Max. temp. meter, latest month
*
7
Daily max. flow /
Min.temp.water, daily
/ Time weighted average temp. meter, daily
**
9
Measuring the water temperature is only valid for meter sizes 1.6 and 2.5m
3
/h
Display resolution
00001 m³
0
00000.1 m³
1
00000.01 m³
2
00000.001 m³
3
Encryption level
No encryption
0
Utility encryption (only available for selected markets)
2
Encryption with separately forwarded key
3
Unless otherwise stated in the order,
Kamstrup supplies the following:
01
002
000
1
3
5
3
3