TECHNICAL DESCRIPTION flowIQ® 3100
48 Kamstrup A/S • Technical Description • 5512-1242_B1_GB • 05.2015
13.3 Data content
The data content of the data transmission partly depends on the configuration.
See document 5512-1034 Tecnical Description for Wireless M-Bus.
13.1 Encryption
flowIQ® 3100 can be ordered without or with encryption of data transmission. If encryption of data is
selected, it consists of 128 bit AES counter mode encryption. Kamstrup A/S recommends encryption.
*)
Meters produced for Russia will always be WITHOUT encryption.
14 Communication (KMP)
The meter has an optical communication interface on the front. The interface communicates at 1200 baud
and can be used if an optical reading head is connected to METERTOOL and LogView.
14.1 Optical eye activation
In order to limit current consumption the optical eye is usually switched off. The meter's optical
communication is automatically switched on 4 sec. after having placed the magnetic optical reading head
on the meter.
15 METERTOOL for flowIQ® 3100/MULTICAL® 21/flowIQ®21XX
METERTOOL is a PC program, giving access to change the customer selected parameters of a water meter
configuration and read its data memory without dismounting the meter from the installation.
Get further information and technical details on METERTOOL/LogView in document:
5512-1653Technical Description for METERTOOL