9.9.17 Technical specifications
Physical Fully integrated M-Bus interface
Communication
Readout speed 300/2400/9600 baud with automatically speed detection
Communication interval Longer than 1 minute (recommended)
Protocol EN 13757:2013
Configuration METERTOOL HCW via optical read-out head
Power consumption 1 unit load (1.5 mA) per M-Bus slave
Rin / Cin 422 Ω/0.5 nF
Max cable resistance 29 Ω/180 nF per pair
Operational temperature 5 - 55°C
Markings/approvals
- EN 13757CE approval
- MID
Ordering
See section
Type overview and Configuration

Table of Contents