TECHNICAL DESCRIPTION flowIQ® 3100
12 Kastup A/S • Tehial Desiptio • 5512-1242_D_GB • 09.2016
4 Type overview
Type 031-
฀฀
0
฀฀
Communication
Wireless M-Bus, 868 MHz, mode C1 ver. 2
46
Wireless M-Bus, 868 MHz, mode T1 OMS ver. 2
47
Wired M-Bus
30
Supply
 eas atte life, C-cell
C
Meter size
Q
3
[m³/h]
Connection
Length [mm]
Dynamic range
1.6
G¾B (R½)
110
100
A
2.5
G¾B (R½)
110
100
B
2.5
G1B (R¾)
190
100
C
2.5
G5/4B (R1)
175
100
2
4.0
G5/4B (R1)
175
100
3
4.0
G5/4B (R1)
260
100
G
6.3
G5/4B (R1)
260
100
H
10
G2B(R1½)
300
100
J
16
DN50
270
100
L
25
DN65
300
100
M
40
DN80
300
100
N
Meter type
Cold water meter, T30 or T50 (MID)
8
Country Code
XX
The type number of the meter
cannot be changed after factory programming.
The country code can also be used for:
• Laguage ad appoal o tpe lael
• Tepeatue lass of flo seso T o T
4.1 Accessories