EasyManuals Logo

Kamstrup flowIQ 3100 User Manual

Kamstrup flowIQ 3100
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
TECHNICAL DESCRIPTION flowIQ® 3100
12 Kastup A/S • Tehial Desiptio • 5512-1242_D_GB • 09.2016
4 Type overview
Type 031-
฀฀
0
฀฀
Communication
Wireless M-Bus, 868 MHz, mode C1 ver. 2
46
Wireless M-Bus, 868 MHz, mode T1 OMS ver. 2
47
Wired M-Bus
30
Supply
 eas atte life, C-cell
C
Meter size
Q
3
[m³/h]
Connection
Length [mm]
Dynamic range
1.6
G¾B (R½)
110
100
A
2.5
G¾B (R½)
110
100
B
2.5
G1B (R¾)
190
100
C
2.5
G5/4B (R1)
175
100
2
4.0
G5/4B (R1)
175
100
3
4.0
G5/4B (R1)
260
100
G
6.3
G5/4B (R1)
260
100
H
10
G2B(R1½)
300
100
J
16
DN50
270
100
L
25
DN65
300
100
M
40
DN80
300
100
N
Meter type
Cold water meter, T30 or T50 (MID)
8
Country Code
XX
The type number of the meter
cannot be changed after factory programming.
The country code can also be used for:
• Laguage ad appoal o tpe lael
• Tepeatue lass of flo seso T o T
4.1 Accessories
An overview of suitable accessories can be found in the document:
Accessories List 5810-1270

Table of Contents

Other manuals for Kamstrup flowIQ 3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kamstrup flowIQ 3100 and is the answer not in the manual?

Kamstrup flowIQ 3100 Specifications

General IconGeneral
BrandKamstrup
ModelflowIQ 3100
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals