24 Kamstrup A/S • 5512603_C1_GB_03.2016
MULTICAL® 801
9 Information codes ”INFO”
MULTICAL® 801 constntly monitors series of importnt functions. If
serious error occurs in the mesuring system or in the instlltion, ”INFO”
ppers in the disply nd n info code cn be red by ctivting the upper
front plte button until the mesuring unit shows ”INFO” in the disply. The
info code is only visible while the error exists.
Info
code
Description Response time
0 No irregulrities -
1 Supply voltge hs been cut off -
8 Temperture sensor T1 outside
mesuring rnge
1…10 min.
4 Temperture sensor T2 outside
mesuring rnge
1…10 min.
32 Temperture sensor T3 outside
mesuring rnge
1…10 min.
64 Lek in the cold-wter system 24 hours
256 Lek in the heting system 24 hours
512 Burst in the heting system 120 sec.
ULTRAFLOW® 54 info (ctivted when CCC=4XX)
16 Flow sensor V1, Dtcomm error After reset nd 1 dy (00:00)
1024 Flow sensor V2, Dtcomm error After reset nd 1 dy (00:00)
2048 Flow sensor V1, Wrong meter fctor After reset nd 1 dy (00:00)
128 Flow sensor V2, Wrong meter fctor After reset nd 1 dy (00:00)
4096 Flow sensor V1, Signl too low (Air) After reset nd 1 dy (00:00)
8192 Flow sensor V2, Signl too low (Air) After reset nd 1 dy (00:00)
16384 Flow sensor V1, Wrong flow direction After reset nd 1 dy (00:00)
32768 Flow sensor V2, Wrong flow direction After reset nd 1 dy (00:00)