6 7
KEB COMBIVERT F4-C
6
Name: Basis
12.03.99
Keep on Running Functions
© KEB Antriebstechnik, 1997
All Rights reserved
Functional Description
Chapter Section Page
Date
Param. Adr.
min
max
default
ENTER
PROG.
R/W
Step
Pn.12 220Ch ✔✔- 0 8 1 - Bit-coded
Pn.13 220Dh ✔✔- 10 % 199 % (200 = oFF) 1 % 200 % % referring to rated inverter current
Pn.14 220Eh ✔✔- 0,00 s 300,00 s 0,01s 10,00 s -
Used Parameters
Picture 6.7.2.b Example for constant current limit
Actual frequeny (ru.3)
Inverter status (ru.0)
Actual load (ru.7)
adjusted