EasyManua.ls Logo

KEB COMBIVERT F4-C - Page 180

KEB COMBIVERT F4-C
283 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
ANTRIEBSTECHNIK
6
915
KEB COMBIVERT F4-C
Name: Basis
29.01.98
6
ANTRIEBSTECHNIK
Section
Page
Date
© KEB Antriebstechnik, 1997
All Rights reserved
Chapter
Functional DescriptionSpecial Functions
Param. Adr.
min
max
default
ENTER
PROG.
R/W
Step
Used Parameters
Setpoint Value and Direction of
Rotation (oP.0)
In order to adjust the setpoint value via the motor potentiometer oP.0 (set value source)
must be adjusted accordingly.
Rotation oP.0 Set Value
Keyboard/Bus 15 Motor potent.
Terminal strip 16 Motor potent.
±Motor potent. 17 Motor potent.
Motor Potentiometer/Target
(oP.31)
Apart from the setpoint value setting the motor potentiometer can be assigned to
further functions. For that the actual percentage (ru.34) is represented on a defined
parameter, the target parameter, and can change it. Possible target parameters are:
oP.31 Motor potentiometer / Target
0 no target parameter
1 dr.35 gearbox factor channel 1 (62,5%)
2 dr.36 gearbox factor channel 2 (62,5%)
(max. parameter value at ...% attained)
To prevent any dead travel in the motor potentiometer the maximum operating range
(oP.28) should be adjusted to the corresponding percentage.
ru.34 2022h - - 100,00 100,00 0,01 0 -
oP.0 2100h ✔✔ 0 26 1 1 Value 15, 16 o. 17
oP.26 211Ah - - - 0 15 1 8 -
oP.27 211Bh - - - -100,00 100,00 0,01 0,00 -
oP.28 211Ch - - - -100,00 100,00 0,01 0,00 -
oP.29 211Dh - - - 0 300,00 s 0,01s 131,00s -
oP.30 211Eh - 0810-
oP.31 211Fh - 0210-
di.3 2903h
:: - 0 16 1 0 Adjust value 7, 8 o. 10
di.10 290Ah