6 9
KEB COMBIVERT F4-C
24
Name: Basis
29.01.98
Name: Basis
Chapter Section Page Date
© KEB Antriebstechnik, 1997
All Rights reserved
Functional Description Special Functions
Param. Adr.
min
max
default
ENTER
PROG.
R/W
Step
ru.43 202Bh - - - -32767 32767 1 - -
ud.87 2657h -- 0 4 1 0 -
ud.88 2658h - - -9999 9999 1 1500 -
ud.89 2659h - - 1 9999 1 4000 -
ud.90 265Ah - - -9999 9999 1 0 -
ud.91 265Bh -- 0 4 1 0 -
ud.88 = delta Y = 300
delta f 40 Hz
ud.89 = = = 3200
Resolution 0,0125 Hz
ud.88 delta Y 300
Desired unit = = = (if necessary shorten)
ud.89 nonstandardized value 3200
f
B
- delta f 50 Hz - 40 Hz
Offset ud.90 = = = 800
0,0125 Hz 0,0125 Hz
Following values are to be entered as resolution:
at ud.87 = 0 and 1
frequency mode ud.11 = 0 (409,5875 Hz) resolution = 0,0125 Hz
= 1 (819,17 Hz) resolution = 0,025 Hz
= 2 (1638,35 Hz) resolution = 0,05 Hz
at ud.87 = 2 und 3
resolution = 0,5 U/min
at ud.87 = 4
resolution = 1 %
Calculation of ud.88 / ud.89
Adjust Offset ud.90
Resolutions
Used Parameters