Loading...
6
117
24.06.02
KEB COMBIVERT F5-G / B
Name: Basis
6
Functional Description
© KEB Antriebstechnik, 2002
All rights reserved
Chapter Section PageDate
Operating and Appliance Data
Adr.
min max
default
Adr.
min max
default
0E01h
0.1
A
-
7100
6.1.6 Description of the In-Parameters
0E00h
In. 0 Inverter type
1
hex
-
FFFFh0h
The inverter type is displayed in hexadecimal numbers. The bits have following meaning:
Bit 0-4 Unit size 05, 07, 09 etc.
Bit 5 Voltage class 0 = 230 V
1 = 400 V
Bit 6 Phase number 0 = 1-phase
1 = 3-phase
Bit 7 free
Bit 8-12 Housing 0 = A 10 = K 20 = U
1 = B 11 = L 21 = V
2 = C 12 = M 22 = W
3 = D 13 = N 23 = X
4 = E 14 = O 24 = Y
5 = F 15 = P 25 = Z
6 = G 16 = Q
7 = H 17 = R
8 = I 18 = S
9 = J 19 = T
Bit 13-15 Control 0 = G
1 = M
2 = B
3 = S
4 = A
Example:
hex 0 4 0 A
binary 0000010000001010
decimal 0 4 0 0 10
=> 10.F5 G-Control / E-housing / 230V / 1ph.
In. 1 Rated inverter current
Display of the rated inverter current in A. The value is determined from the power circuit identification (P-ID) and cannot
be changed.