6 1
Name: Basis
KEB COMBIVERT F5-G / B
18
24.06.02
Functional Description
© KEB Antriebstechnik, 2002
All rights reserved
Chapter Section Page Date
Operating and Appliance Data
Adr.
min max
default
0E03h
Adr.
min max
default
0E06h
Adr.
min max
default
0E07h
0.01
-
-
9.990.00
0.1
-
-
--
1
-
P-ID
40
Display of the maximum possible switching frequency in kHz for this inverter. The displayed value corresponds to
following switching frequencies:
0: 2 kHz / 1: 4 kHz / 2: 8 kHz / 3: 12 kHz / 4: 16 kHz
In. 3 Max. switching frequency
Display of the software version number..
1. and 2. digit: Software version (z.B. 2.1)
3. digit: Special version (0 = standard)
In. 6 Software version
Display of the software date. The value contains day, month and year, from the year only the last digit is indicated.
Example: Display = 2102.0
Date = 21.02.2000
In. 7 Software date
Adr.
min max
default
0E04h
1
-
P-ID
40
Display of the rated switching frequency. The displayed value corresponds to the following switching frequencies:
0: 2 kHz / 1: 4 kHz / 2: 8 kHz / 3: 12 kHz / 4: 16 kHz
In. 4 Rated switching frequency