EasyManua.ls Logo

KEB COMBIVERT F5 BASIC - Page 108

KEB COMBIVERT F5 BASIC
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 1
Name: Basis
KEB COMBIVERT F5-G / B
22
24.06.02
Functional Description
© KEB Antriebstechnik, 2002
All rights reserved
Chapter Section Page Date
Operating and Appliance Data
Adr.
min max
default
000Bh
1
-
5
113
Sy. 11 Baud rate int. bus
With the internal baudrate the transmission rate between operator and inverter is determined. Following values are
possible:
Value Baudrate Value Baudrate Value Baudrate
3 9,6 kBaud 6 55,5 kBaud 9 115,2 kBaud
4 19,2 kBaud 7 57,6 kBaud 10 125 kBaud
5 38,4 kBaud 8 100 kBaud 11 250 kBaud
Adr.
min max
default
0020h
1
-
0
655350
Sy. 32 Scope Timer
The scope timer generates a time period of 1 ms. This can be used by external programs, e.g. Scope, to represent time
patterns. The timer counts from 0...65535 and starts again with 0 after an overflow.
Adr.
min max
default
0009h
0,01
s
0 (off)
10,000 (off)
Sy. 9 HSP5 Watchdaog time
The HSP5 Watchdog-function monitores the communication of the HSP5-interface (control card - operator; or control
card - PC). After expiration of an adjustable time (0,01...10 s) without incoming telegrams, the response adjusted in Pn.5
is triggered. The value „off“ deactivates the function.
Adr.
min max
default
0029h
1
-
0
655350
Sy. 41 Control word high
The control word is used for the status control of the inverter via bus. The control word long (Sy.43) consists of the two
16 bit parameters control word high (Sy.41) and Control word low (Sy.50). The status word is bit-coded. The description
of the individual bits is found in Chapter 11.2.7.
Adr.
min max
default
002Ah
1
-
0
655350
Sy. 42 Status word high
With the status word the current condition of the inverter can be readout. The status word long (Sy.44) consists of the
two 16 bit parameters status word high (Sy.42) and status word low (Sy.51). The status word is bit-coded. The description
of the individual bits is found in Chapter 11.2.7.

Table of Contents

Related product manuals