Loading...
6
49
KEB COMBIVERT F5-G / B
Name: Basis
06.02.02
6
© KEB Antriebstechnik, 2002
All rights reserved
Functional DescriptionSet Value and Ramp Adjustment
Section PageDate Chapter
Fig. 6.4.4 Fixed frequencies
6.4.4 Fixed Frequencies
(oP.18...23)
The KEB COMBIVERT supports up to 3 fixed frequencies for each parameter set,
which can be selected via two digital inputs. With oP.19 and oP.20 the inputs required
for the selection are defined (also see „Digital inputs“ Chapt. 6.3.11). The rotation
direction source for fixed frequency mode is defined with oP.18. The adjustment is
independent of oP.1 and is valid exclusively for the fixed frequencies. The adjustment
of a fixed frequency has priority over the „normal“ setpoint adjustment.
Input fixed frequency 1
Input fixed frequency 2
Fixed frequencies
f1...f3
oP. 18
0
2
1
3
54
6
7
8
9
oP.19 Input selection
Fixed frequency 1
0...4095
(according to table)
oP.20 Input selection
Fixed frequency2
0...4095
(according to table)
Fixed frequency 1
oP.21: -400...400 Hz
Fixed frequency 2
oP.22: -400...400 Hz
Fixed frequency 3
oP.23: -400...400 Hz
Setpoint limits
Digital
oP.2
0-lim. abs. 0-lim. abs. 0-lim. abs. 0-lim. abs.LS no LS
Terminal strip
For / Rev
Terminal strip
Run / Stop
Setpoint-
dependent
DRIVECOM
SY.50
Fixed value
rotation direction source
f1
f2
f3
t
Setpoint
Fig. 6.4.4.a Selection of fixed frequencies
Input
Fixed frequency 1
Input
Fixed frequency 2
Selection of fixed frequencies