Error Assistance
Section PageDate
© KEB Antriebstechnik, 2002
All Rights reserved
Chapter
E.SbuS ERROR bus synchron 23 Sychronization over sercos-bus not possible. Programmed
response “Error, restart after reset” (see chapter 6.7
“Response to errors or warning messages”).
E.SEt ERROR set 39 It has been attempted to select a locked parameter set.
Programmed response “Error, restart after reset” (see chapter
6.7 “Response to errors or warning messages”).
E.SLF ERROR! Software limit switch forward 44 The right software limit switch lies outside the defined limits.
Programmed response “Error, restart after reset” (see chapter
6.7 “Response to errors or warning messages”).
E.SLr ERROR software limit switch reverse 45 The left software limit switch lies outside the defined limits.
Programmed response “Error, restart after reset” (see chapter
6.7 “Response to errors or warning messages”).
E. UP ERROR underpotential 2 Error: Undervoltage (DC-link circuit). Occurs, if DC-link
voltage falls below the permissible value. Causes:
• input voltage too low or instable
• inverter rating too small
• voltage losses through wrong cabling
• the supply voltage through generator / transformer breaks
down at very short ramps
• At F5-G housing B E.UP is also displayed if no
communication takes place between power circuit and control
card.
• Jump factor (Pn.56) too small (see 6.9.20)
• if a digital input was programmed as external error input
with error message E.UP (Pn.65).
E.UPh ERROR Phase failure 3 One phase of the input voltage is missing (ripple-detection)
Warning Messages
A.buS ABN.STOP bus 93 Warning: Watchdog for communication between operator/
control card or operator/PC has responded. The response to
this warning can be programmed (see chapter 6.7 “Response
to errors and warning messages”).
A.dOH ABN.STOP drive over heat 96 The motor temperature has exceeded an adjustable warning
level. The switch off time is started. The response to this
warning can be programmed (see chapter 6.7 “Response to
errors or warning messages”). This warning can be generated
only with a special power circuit.
A. EF ABN.STOP external fault 90 This warning is triggered via an external input. The response
to this warning can be programmed (see chapter 6.7
“Response to errors or warning messages”).
A.ndOH no A. drive overheat 91 The motor temperature is again below the adjusted warning
level. The switch off time is stopped.
A.nOH no A. overheat pow.mod. 88 The heat sink temperature is again below the adjusted
warning level.
A.nOHI no A.STOP overheat int. 92 The temperature in the interior of the inverter is again below
the warning threshold.
A.nOL no ABN.STOP overload 98 Warning: no more overload, OL counter has reached 0 %.
A.nOL2 no ABN.STOP overload 2 101 The cooling time after “Warning! Overload during standstill”
has elapsed. The warning message can be reset.
Display COMBIVIS Value Meaning