KEB COMBIVERT F5
8
Name: Basis
10.04.02
Error Assistance
Chapter Section Page Date
© KEB Antriebstechnik, 2002
All Rights reserved
A. OH A.STOP overheat pow.mod 89 A level can be defined, when it is exceeded this warning is
output. A response to this warning can be programmed (see
chapter 6.7 “Response to errors or warning messages”).
A.OH2 ABN.STOP motor protect. 97 Warning: electronic motor protective relay has tripped. The
response to this warning can be programmed (see chapter
6.7 “Response to error or warning messages”).
A.OHI ABN.STOP overheat int. 87 The temperature in the interior of the inverter lies above the
permissible level. The switch off time was started. The
programmed response to this warning message is executed
(see chapter 6.7 “Response to errors or warning messages”).
A. OL ABN.STOP overload 99 A level between 0 and 100 % of the load counter can be
adjusted, when it is exceeded this warning is output. The
response to this warning can be programmed (see chapter
6.7 “Response to errors or warning messages”).
A.OL2 ABN.STOP overload 2 100 The warning is output when the standstill continuous current
is exceeded (see technical data and overload
characteristics). The response to this warning can be
programmed (see chapter 6.7 “Response to errors and
warning messages”). The warning message can only be reset
after the cooling time has elapsed and A.nOL2 is displayed.
A.PrF ABN.STOP prot. rot. for. 94 The drive is driven onto the right limit switch. The response
to this warning can be programmed (see chapter 6.7
“Response to errors and warning messages”).
A.Prr ABN.STOP prot. rot. rev. 95 The drive is driven onto the left limit switch. The response to
this warning can be programmed (see chapter 6.7 “Response
to errors and warning messages”).
A.SbuS ABN.Bus synchron 103 Synchronization over sercos-bus not possible. The response
to this warning can be programmed (see chapter 6.7
“Response to errors and warning messages”).
A.SEt ABN.STOP set 102 Warning: set selection: It has been attempted to select a
locked parameter set. The response to this warning can be
programmed (see chapter 6.7 “Response to errors or warning
messages”).
A.SLF ABN.Software limit switch forward 104 The right software limit switch lies outside the defined limits.
The response to this warning can be programmed (see
chapter 6.7 “Response to errors or warning messages”).
A.SLr ABN.Software limit switch reverse 105 The left software limit switch lies outside the defined limits.
The response to this warning can be programmed (see
chapter 6.7 “Response to errors or warning messages”).