Functional Description
© KEB Antriebstechnik, 2002
All rights reserved
Chapter Section Page Date
Operating and Appliance Data
Adr.
min max
default
Adr.
min max
default
ud.3
!ud.2!
0201h
ru. 1 Set value display
0.0125
Hz
-
400-400
Display of current setpoint frequency. The operator displays additionally „noP“ and „LS“ if the control release or the
direction of rotation are not switched.
A counter-clockwise rotary field (reverse) is represented by a negative sign. Precondition is the phase-correct connection
of the motor.
0203h
ru. 3 Actual frequency display
0.0125
Hz
-
400-400
The indicated actual frequency corresponds to the rotary field frequency given out at the inverter output. The representation
is the same as at ru.1.
clockwise
rotation
(forward)
counter-clockwise
rotation
(reverse)
!ud.2!
!ud.2!
Adr.
min max
default
6.1.5 Description of the ru-Parameters
ru. 0 Inverter status
0200h
0
78
-
-
-
The inverter status shows the current operating condition of the inverter (e.g. constant forward run, standstill etc.). In
the case of an error the current error message is displayed, even if the display has already been reset with ENTER
(error-LED on the operator is still blinking). For more information about status messages as well as its cause and
removal refer to Chapter 9 „Error Diagnosis“.
Adr.
min max
default
0202h
ru. 2 Ramp output display
0,0125
Hz
-
400-400
The indicated actual frequency corresponds to the rotary field frequency given out at the ramp output. The representation
is the same as at ru.1.
!ud.2!
!ud.2!