Name: Basis
KEB COMBIVERT F5-G / B
8
24.06.02
Functional Description
© KEB Antriebstechnik, 2002
All rights reserved
Chapter Section Page Date
Operating and Appliance Data
Adr.
min max
default
0210h
ru.16 Apparent current / peak value
0.1
A
-
unit-dependent0
ru.16 permits the detection of short-time peak currents within an operating cycle. The highest occurred value of ru.15 is
stored in ru.16. The peak value memory can be cleared by pressing the keys UP, DOWN or ENTER and by bus through
writing any chosen value to the address of ru.16. Switching off the inverter also results in a clearing of the memory.
Adr.
min max
default
Adr.
min max
default
020Dh
ru.13 Actual utilization
1
%
-
2550
Display of the current utilization referred to the rated current of the inverter. Only positive values are indicated, thus it is
not possible to differentiate between a motoric or generatoric operation.
020Eh
ru.14 Peak utilization
1
%
-
2550
ru.14 permits the detection of short-time peak loads within an operating cycle. The highest occurred value of ru.13 is
stored in ru.14. The peak value memory can be cleared by pressing the keys UP, DOWN or ENTER and by bus through
writing any chosen value to the address of ru.14. Switching off the inverter also results in a clearing of the memory.
Adr.
min max
default
020Fh
ru.15 Apparent current
0.1
A
-
unit-dependent0
Display of the current apparent current. The maximum values depend on the size of the inverter.