KEB COMBIVERT F5-G / B
Name: Basis
6
Functional Description
© KEB Antriebstechnik, 2002
All rights reserved
Chapter Section PageDate
Operating and Appliance Data
Adr.
min max
default
021Dh
ru.29 Analog input 2 / display before amplification
0.1
%
-
100-100
This parameter shows the value of the analog signal AN2 on the differential voltage input (terminal X2A.3 / X2A.4)
before signal amplification in percent. In dependence on An.10 the indicated value of 0...±100 % corresponds to:
0...±10 V; 0...±20 mA or 4...20 mA (also see Chapt. 6.2 „Analog inputs“).
Adr.
min max
default
021Eh
ru.30 Analog input 2 / display after amplification
0.1
%
-
400-400
This parameter shows the value of the analog signal AN2 in percent after passing the characteristic amplifier. The range
of indication is limited to ±400 % (also see Chapt. 6.2 „Analog inputs“).
Adr.
min max
default
021Fh
ru.31 Analog input 3 / display before amplification
0.1
%
-
100-100
This parameter shows the value of the analog signal on the optionally analog input AN3 before signal amplification in
percent. The indicated value of 0...±100 % corresponds to 0...±10 V (also see Chapt. 6.2 „Analog inputs“).
Adr.
min max
default
0220h
ru.32 Analog input 3 / display after amplification
0.1
%
-
400-400
This parameter shows the value of the analog signal AN3 in percent after passing the characteristic amplifier. The range
of indication is limited to ±400 % (also see Chapt. 6.2 „Analog inputs“).