EasyManua.ls Logo

KEB COMBIVERT F5-H - Password Structure; Password Levels

KEB COMBIVERT F5-H
552 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Password input
© KEB, 2012-10 COMBIVERT F5-A, -E, -H Page 4.2 - 3
4
4.2 Password structure
The KEB COMBIVERT is provided with extensive password protection. The different passwords are used to
- change the operating mode
- set a write protection
- activate the service mode
- switch to the drive-mode
Depending on the actual operating mode the password can be entered in the following parameters:
when the CP-mode is active
when the application mode is active
4.2.1 Password levels
The parameter value of the above parameters shows the actual password level. Following indications are
possible:
CP - read only
Only the customer parameter group is visible, ex-
cept for CP. 0 all parameters are in the read-only
status (see chapter 4.3).
CP - on
Only the customer parameter group is visible. All
parameters can be changed.
CP - Service
Like CP-on, but the parameter identication is
indicated according to the original parameter (see
chapter 4.3)
Application
All application parameters are visible and can be
changed. The CP-parameters are not visible.
Drive mode
The Drive-Mode is a special operating mode, here
the unit can be put into operation via the operator
(see chapter 4.4).