Page 10.1 - 14 COMBIVERT F5-A, -E, -H © KEB, 2012-10
Network components
10.1.9.9 Speed setting via bus
Status word long (SY.44)
The control word long (32 Bit) consists of SY.51 and SY.42.
Set speed value (SY.52)
Setting of the set speed value in the range of ±16000 rpm. The rotation source is determined via oP.01 (like
other absolute setpoint sources). The setpoint source oP.0 must be adjusted to „5“ via Sy.52 for setpoint setting.
Actual speed value (SY.53)
The actual speed can be read out in rpm with this parameter. The direction of rotation is signalled by the sign.