Handheld Terminal KeTop - Specific Operating Instructions
User's Manual, version: 3.1 / material no.: 57448 97
© KEBA 2006
Calibration of Joystick
A number is displayed next to the slide bar. During calibration, this number
specifies the current value of the ADC (value range: 0..1024) and only con-
trols the function. After calibration, the number specifies the current value of
the joystick/potentiometer (value range: -15 .. 15 for each joystick axis).
This value is also the value the KeTop API function KtpGetJoystickPos
supplies to the application.
Calibration of Potentiometer
A number is displayed next to the slide bar. During calibration, this number
specifies the current value of the ADC (value range: 0..1024) and only con-
trols the function. After calibration, the number specifies the current value of
the potentiometer (value range: 0 ...127).
This value is also the value the KeTop API function KtpGetOverridePoti
supplies to the application.