5.2.2 Setting the bus address on the slave
The SERCOS parameter ID/S-0-1040.0.0 is used to set the bus address. This
parameter can be written with the aid of DriveManager 5. The address set must be
unique, i.e. each address is only allowed to be used once in a SERCOS ring.
SERCOS III also supports the automatic addressing of the slaves. If the address 0 is
entered in IDN/S-1040-0-0 in all slaves in a ring, then the addressing is undertaken
automatically by the master as the bus is booted, provided the master supports this
type of addressing.