Data transfer
ServoOne User Manual SERCOS II and III
ID no.: 1108.26B.3-00 Date: 04/2020
Data transfer
7.5.2 SERCOS III IP address
The IP address for the SERCOS III option card is set with the aid of ID/S-0-1020. Here
it is imperative to note that the SERCOS III IP address is not the same as the standard
IP address for the ServoOne (parameter 671). The two IP addresses must differ as a
minimum in the 3rd number group, as specied for example in the factory setting:
Standard IP: 192.168.39.5
SERCOS III – IP: 192.168.38.5
Subnet Mask: 255.255.255.0
If both addresses are the same, then an error message will be output the next time the
ServoOne is restarted. So that communication via TCP/IP is also possible, the address
changed last is reset to its old value.
After the change to the default address and the SERCOS III IP address, the new value
is only applied after the ServoOne is restarted.