Specifications 3
Keysight 11713D/E Operating and Service Manual 37
Remote programming characteristics
Environmental Specifications
Keysight 11713D/E attenuator/switch drivers are designed to fully comply with Keysight
Technologies’ product operating environmental specifications as shown in the table below.
Interface
GPIB interface operates to IEEE 488.2 and IEC 65
10/100 BaseT LAN interface
USB 2.0 interface
Command language SCPI standard interface commands (Keysight 11713A backward compatible)
GPIB compatibility SH0, AH1, T0, TE0, L2, LE0, SR0, RL1, PP0, DC0, DT0, C0
Table 3-3 11713D/E environmental specifications
Temperature
–Operating
–Storage
0 °C to +50 °C
–40 °C to +70°C
Humidity
–Operating
–Storage
– Condensing
95% RH up to 40 °C, decreases linearly to 45% RH at 50 °C, non-condensing;
95% RH at 40°C, 5 days cyclic
45% RH at 50°C, non-condensing
95% RH at 40°C, 5 hours (condensation 15 minutes)
Shock
– End-user handling
– Bench handling
– Functional
– Transportation
Half-sine: 2 to 3 ms duration, 60 in/s (1.6 ms) delta-V
Per MIL-PRF-28800F
Half-sine: 11 ms duration, 30 grms
Trapezoidal: 18 to 22 ms duration, 337 in/s (8.56 ms) delta-V
Vibration
– Operating (Random)
– Survival (Random)
– Swept-sine
0.21 G rms, 5 to 500 Hz, 10 min/axis
2.09 G rms, 5 to 500 Hz, 10 min/axis
0.5 G rms, 5 to 500 Hz, 10 min/axis
Altitude
–Operating
– Non-operating
≤ 4,000 meters (13,123 feet)
≤ 15,300 meters (50,000 feet)