General Information 1
Series E4360 User’s Guide 11
Output Features
Low output capacitance
Low output capacitance allows faster output response time in
constant current operation.
Fast up/down voltage
programming
Less than 8 millisecond response time from 10% to 90% of the
output rating.
Fast I-V curve change
Fast I-V curve change in both SAS mode and Table mode.
Fast switching recovery
Switching recovery is less than 5 microseconds.
Programmable voltage
and current
Full programming capability is provided for the entire range of
output voltage and current. Outputs can operate as either constant
voltage (CV) or constant current (CC) sources.
Output paralleling for
higher power
Two o
utputs can be configured to act as
a single output with higher
current and power capability. Up to four outputs can be paralleled.
R
emote voltage sensing
Two remote sensing terminals are provided for each output. See
chapter 2 for details.
Voltage and current
measurements
All output modules can measure their own output voltage and
current.
Voltage, current, and
temperature protectio
n
Each output has over
-voltage, over-current, over-temperature
, and
over
-switching protection. Over-voltage and over-current
protection are programmable. When activated, the protection
circuits cause the voltage to go to zero, the output to be disabled,
and the protection status to be reported.
System Features
SCPI language
The instrument is compatible with the Standard Commands for
Programmable Instruments (SCPI).
Fast command
processing
Command processing time of less than 1 millisecond per
command.
C
hoice of three
interfaces
GPIB (IEEE
-
488), LAN, and USB remote programming interfaces are
built in.
Front panel I/O setup
Menus let you set up GPIB and LAN parameters from the front
panel. See chapter 3 for details.
Built
-in Web server
A built
-in Web server lets you control the instrument directly from
an internet browser on your computer. See chapter 3 for details.
Internal table memory
Up to 30 tables can be stored in volatile memory; up to
30 in non-volatile
memory
Real
-time status
information
The front panel indicates the status of each output. It also indicates
when a protection shut-down has occurred.
Module identification
Each module has identifying data stored in non
-volatile memory.
Information includes model number, serial number, and option
s.
This information can be displayed on the front panel.
Fan speed control
Fan speed control circuits minimize acoustic noise.

Other manuals for Keysight Technologies E4360 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies E4360 Series and is the answer not in the manual?

Keysight Technologies E4360 Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelE4360 Series
CategorySwitch
LanguageEnglish

Related product manuals