95
Command Reference
Calculate Subsystem
Marker Function
:CALCulate:MARKer[1]|2|3|4|5|6:FUNCtion
FCOunt|NOISe|OFF
:CALCulate:MARKer[1]|2|3|4|5|6:FUNCtion?
This command selects the marker function for the designated
marker.
COunt refers to the frequency counter function.
NOISe refers to the noise measurement function.
OFF refers to the normal function.
*RST: 1 kHz
Example: :CALCulate:MARKer1:FUNCtion NOISe
Key access: Marker
> Function
Peak Search
:CALCulate:MARKer[1]|2|3|4|5|6:MAXimum
Performs a peak search based on the search mode settings
of
:CALCulate:MARKer[1]|2|3|4|5|6:FUNCtion
FCOunt|NOISe|OFF and :CALCu-
late:MARKer:PEAK:SEARch:MODE MAXimum|MINimum.
Example: :CALCulate:MARKer:PEAK:SEARch:MODE MAXimum
Key access: Shift > Peak > Peak Search
Next Peak Search
:CALCulate:MARKer[1]|2|3|4|5|6:MAXimum:NEXT
Places the selected marker on the next highest signal peak of
the current marked peak.
Example: :CALCulate:MARKer1:MAXimum:NEXT
Key access: Shift > Peak > Next Peak