Command Reference
Demodulation Option Subsystem
180
FM Y Reference Position
:DISPlay:AMA:VIEW:WINDow:TRACe:Y[:SCALe]:RPOSi-
tion TOP|CENTer|BOTTom
:DISPlay:AMA:VIEW:WINDow:TRACe:Y[:SCALe]:RPOSi-
tion?
Use this command to specify reference position of Y axis.
Range: TOP, CENTer, BOTTom
Example: :DISPlay:AMA:VIEW:WINDow:TRACe:Y:RPOSition TOP
Key access: Shift > Disp > Y Scale > Ref Position
FM Y Scale Coupling State
:DISPlay:AMA:VIEW:WINDow:TRACe:Y[:SCALe]:COUPle
0|1|OFF|ON
:DISPlay:AMA:VIEW:WINDow:TRACe:Y[:SCALe]:COUPle?
Use this command to turn on/off scale coupling state of Y
axis.
Example: :DISPlay:AMA:VIEW:WINDow:TRACe:Y:COUPle 1
Key access: Shift > Disp > Y Scale > Scale Coupling
ASK Demodulation Subsection
Switch To ASK
:INSTrument:MEASure ASK
Use this command to switch to ASK demodulation analysis.
ASK Average Count State
[:SENSe]:DMA:AVERage OFF|ON|0|1
[:SENSe]:DMA:AVERage?
Use this command to turn on/of average operation.
Example: :DMA:AVERage 1
Key access: Meas > Average Number