EasyManua.ls Logo

Keysight N9322C - ASK Demodulation Subsection

Keysight N9322C
223 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Reference
Demodulation Option Subsystem
180
FM Y Reference Position
:DISPlay:AMA:VIEW:WINDow:TRACe:Y[:SCALe]:RPOSi-
tion TOP|CENTer|BOTTom
:DISPlay:AMA:VIEW:WINDow:TRACe:Y[:SCALe]:RPOSi-
tion?
Use this command to specify reference position of Y axis.
Range: TOP, CENTer, BOTTom
Example: :DISPlay:AMA:VIEW:WINDow:TRACe:Y:RPOSition TOP
Key access: Shift > Disp > Y Scale > Ref Position
FM Y Scale Coupling State
:DISPlay:AMA:VIEW:WINDow:TRACe:Y[:SCALe]:COUPle
0|1|OFF|ON
:DISPlay:AMA:VIEW:WINDow:TRACe:Y[:SCALe]:COUPle?
Use this command to turn on/off scale coupling state of Y
axis.
Example: :DISPlay:AMA:VIEW:WINDow:TRACe:Y:COUPle 1
Key access: Shift > Disp > Y Scale > Scale Coupling
ASK Demodulation Subsection
Switch To ASK
:INSTrument:MEASure ASK
Use this command to switch to ASK demodulation analysis.
ASK Average Count State
[:SENSe]:DMA:AVERage OFF|ON|0|1
[:SENSe]:DMA:AVERage?
Use this command to turn on/of average operation.
Example: :DMA:AVERage 1
Key access: Meas > Average Number

Table of Contents

Related product manuals