Command Reference
Power Measurement Subsystem
114
Channel Power RRC Filter Bandwidth
[:SENSe]:CHPower:RRC:BW <value>
[:SENSe]:CHPower:RRC:BW?
Use this command to set the bandwidth of RRC filter in
channel power test.
Example: :CHPower:RRC:BW 2 MHZ
Key access: Meas > More > Filter BW
OBW Subsection
Select the measurement method of OBW
[:SENSe]:OBW:METHod PERCent|DBC
[:SENSe]:OBW:METHod?
This command toggles the method of OBW measurement
between percent and dBc.
*RST: Percent
Example: :CHPower:RRC:BW 2 MHZ
Key access: Meas > Occupied BW > Method
Set percentage (%) method of OBW
[:SENSe]:OBW:PERCent <para>
[:SENSe]:OBW:PERCent?
edit the percentage of signal power used when determining
the occupied bandwidth. Press {%} to set the percentage
ranging from 10.00% to 99.99%.
*RST: 99
Range: 10 to 99
Example: :OBW:PERCent 22.32
Key access: Meas > Occupied BW > %