EasyManuals Logo

Keysight N9322C User Manual

Keysight N9322C
223 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #155 background imageLoading...
Page #155 background image
147
Command Reference
Channel Scanner Option Subsystem
Channel Scanner Option Subsystem
The Channel Scanner Option Subsystem provides you the
SCPI command reference for the channel scanner function.
Use the command :INSTrument SA, and command
:INSTrument:MEASure CHScanner to access this
subsystem.
Option SCN is required to enable the channel scanner
function.
Channel Scanner SWEep Subsection
Sweep Mode
:CHSCanner:SWEep:MODE LIST|TOP|BOTtom
:CHSCanner:SWEep:MODE?
Toggles the channel scanner sweep mode between List mode,
Top N mode and Bottom N mode.
Range: LIST, TOP, BOTtom
Example: :CHSCanner:SWEep:MODE LIST
Key access: Meas > Channel Scanner > Scan Mode
Top N Number
:CHSCanner:SWEep:TOP <value>
:CHSCanner:SWEep:TOP?
This command specify the scanning channel number of Top
N mode. Need to switch to Top N sweep mode before using
this command.
Range: 1 to 20
Example: :CHSCanner:SWEep:TOP 10
Key access: Meas > Channel Scanner > Scan Mode > Top N

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight N9322C and is the answer not in the manual?

Keysight N9322C Specifications

General IconGeneral
BrandKeysight
ModelN9322C
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals