Command Reference
Spectrum Monitor Option Subsystem
132
Spectrogram Save File Type
[:SENSe]:SPECtrogram:SAVE:FTYPe TRC|CSV
[:SENSe]:SPECtrogram:SAVE:FTYPe?
Use this command to switch the spectrogram test result type
between TRC and CSV.
Example: :SPECtrogram:SAVE:FTYPe TRC
Key access: Meas > File Logging > File Type
Spectrogram Save File Size
[:SENSe]:SPECtrogram:SAVE:FSIZe <int>
[:SENSe]:SPECtrogram:SAVE:FSIZe?
Use this command to set the maximum number of trace
(frame) saved in one spectrogram test result file.
Range: 1 to 1500 frames
Example: :SPECtrogram:SAVE:FSIZe 1400
Key access: Meas > Spectrum Monitor > File Logging > File Size
Spectrogram Marker Y Value
[:SENSe]:SPECtrogram:MARKer[1]|2:Y?
Use this command to query the Marker Y axis measurement
result in spectrogram measurement.
Example: :SPECtrogram:MARKer:Y?