Command Reference
Demodulation Option Subsystem
182
ASK Reference Filter
[:SENSe]:DMA:RADio:STANdard:FILTer:REFerence
RNYQuist|NYQuist|GAUSsian|NONE
[:SENSe]:DMA:RADio:STANdard:FILTer:REFerence?
Use this command to specify reference filter in ASK
demodulation analysis.
Range: RNYQuist, NYQuist, GAUSsian, NONE
Example: :DMA:RADio:STANdard:FILTer:REFerence RNYQuist
Key access: Meas > Filter Setup > Ref Filter
ASK Filter Symbols
[:SENSe]:DMA:RADio:STANdard:FILTer:SYMBol <
integer >
[:SENSe]:DMA:RADio:STANdard:FILTer:SYMBol?
Use this command to specify ASK filter symbols.
Range: 2 to 25
Example: :DMA:RADio:STANdard:FILTer:SYMBol 4
Key access: Meas > Filter Setup > Filter Symbols
ASK Alpha/BbT
[:SENSe]:DMA:RADio:STANdard:ALPHa <real>
[:SENSe]:DMA:RADio:STANdard:ALPHa?
Use this command to specify the filter Alpha/Bbt value.
Range: 0.2 to 1
Example: :DMA:RADio:STANdard:ALPHa 0.2
Key access: Meas > Filter Setup > Alpha/BbT