Result:
filter
U
=1740
Calculate
demand
V
according to the required speed :
rpm
V
, (Encoder_R:10000 inc/r)
Result:
8192000
demand
V
Calculate
Factor
according to
filter
U
and
demand
V
:
*
demand filter
V Factor U
Result:
Factor
=4708
Calculate
log1_Ana Dead
according to the required dead zone voltage:
8191/10 log1_ /
dead
v Ana Dead U
Result:
log1_Ana Dead
=409
Calculate
log1_Ana Offset
according to the required offset voltage:
8191/10 log1_ /
shift
v Ana Offset U
Result:
log1_Ana Offset
=819
The following changes are required on the basis of Example 7-3.
Table 7-15 Parameter settings in Example 7-6
d3.23
Analog1_Dead
Sets dead zone data for
external analog signal 1
Set to 409
d3.24
Analog1_Offset
Sets offset data for
external analog signal 1
Set to 819
d3.29
Analog_Speed_Factor
Sets the proportion
between analog signals
and output speed
Set to 4708
d3.00
Store_Loop_Data
1: Storing all configured
parameters for the
control loop
10: Initializing all
parameters for the
control loop
Set to 1