Installation and initial operation
4.3. Installing the control systems
WARNING
Switch off the carrier, depressurise and secure to prevent reactivation.
Observe the respective operating instructions and installation instructions for
the control systems CSP and DF4.
With the control system DF10, the hydraulic and electrical connection are
established without an additional installation direct on the NOX Tiltrotator.
Completely unscrew the hydraulic quick couplings. Pay attention to cleanliness
when connecting the hydraulic connections. Remove any attached dirt
Selection of supply and return line
All hydraulic hoses must be dimensioned so the backpressure is minimised.
We recommend selecting the return line to the tank (Tank Line label) and the
supply line (pressure line (Pressure Line label)) according to the sizes in the
Length of the hydraulic hoses!
Note that the hydraulic hoses are not too long, since they would otherwise be
damaged during operational movements, nor are they too short, since they
would otherwise tear during operational movements.
Approved hydraulic fluids
The attachment has been function-tested by the manufacturer.
To protect hydraulic components, use only hydraulic fluid with the ISO viscosity
noted below.
Fresh fluid has an inferior degree of purity. To bring fresh fluid to the required
level of purity before use, refill through a filter or use a filling device.
Mixing hydraulic fluids of types
• HEES, HEPG, HETG and HEPR (quickly biodegradable) or
• mineral oil is not permitted.
We use a hydraulic fluid that is specified in the chapter Oil and grease.
Ensure that the oil you select has the same specifications!
When connecting the electrical connections, note the electrical precautions.
Improper installation can lead to hazardous situations.
In the event of a doubt relating to knowledge or safety, always contact the
supplier or manufacturer.
During installation, the permissible values the chapter Technical data must be