Handling
48
TR07-TR11-TR14-TR19-TR25
30.03.2020
WARNING
• Check lock by carrying out a movement cycle, and visual and safety check.
• If any anomalies occur, cease working immediately.
• Report and/or rectify faults.
• Switch off the carrier, depressurise and secure to prevent reactivation.
5.2. Dismantling the attachment
• Set the attachment down on the ground.
• Unlock the quick coupler.
• Tilt/roll out the bucket cylinder or quick coupler and tilt the quick coupler out
of the adapter.
• Carefully disengage the quick coupler from the coupling shaft.