EasyManua.ls Logo

KINSHOFER TR07 - Cleaning and Care

Default Icon
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cleanin
g and care
30.03.2020
TR07-TR11-TR14-TR19-TR25
55
7. Cleaning and care
• The cleaning of the attachments should be carried out on a suitable
surface with an oil separator.
• Adjust the cleaning intervals to the operating conditions,
at least once weekly (see chapter Maintenance and service)!
Notice
Paint damage, damage to seals and bearings, oil leaks and other damage are
possible if cleaning is not carried out properly.
1. The attachment can be cleaned with the help of compressed air:
• If the attachment is dry.
• max. 1 MPa (10 bar) air pressure.
• min. 400 mm nozzle distance.
2. The attachment can be cleaned with the help of a high pressure cleaner:
• max. 80 °C water temperature.
• max. 7 MPa (70 bar) water pressure.
• min. 400 mm nozzle distance.
• Never clean seals and seal gaps directly with a pressure washer.
• The paint requires two weeks, to harden completely after
commissioning or after being repainted. Do not use a pressure washer
during this period.
Every time after cleaning, the attachment must be lubricated and a functional
check carried out, see chapter Technical data / Overview greasing point and
chapter Assembly and commissioning / Functional checks.
Lubrication and
Functional checks

Table of Contents