Fertilizer
Loosen " lock nut that secures arm with pointer and rotate scale flange with adjustment wrench until pointer is over
desired scale setting. Tighten " lock nut. DO NOT OVERTIGHTEN.
NOTE: Periodically check flow to all rows. Set rate is delivered to remaining rows if one or more lines are
plugged.
OPTIONAL PISTON PUMP
NOTE: Delivery rate chart in Rate Chart section of this manual provides approximate application rate only.
Delivery varies with temperature and fertilizer.
Piston pump Adjusting delivery rate
NOTE: Keep manuals shipped with pump and flow divider with this manual.
CLEANING
Clean tanks, hoses, and metering pump thoroughly with water at end of planting
season or prior to an extended period of non-use. Do not allow fertilizer to
crystallize from cold temperature or evaporation.
On machines equipped with piston pump, take apart and clean strainer located
between piston pump and ball valve daily. Remove the end cap to clean the
screen. See Piston Pump Storage in Maintenance Section of this manual.
Screen
End cap