2-4
Fire Hazard
Shut off gas supply line valve.
Make all conversions before turning
gas supply valve back on.
Failure to follow these instructions can
result in explosion, fire, or other injury.
L.P. GAS CONVERSION
NOTE: Gas conversion from Natural to L.P.
gas must be done by a qualified installer.
Examples of a qualified installer includes
licensed heating personnel, authorized gas
company personnel, and authorized ser-
vice personnel.
L.P. gas must not be used unless the L.P.
conversion has been made using the kit that is
included with this range. See the “Gas Supply
Requirements” starting on page 2-1.
1. Check to make sure that the main gas
supply line to the range has been shut off,
(see below), and that the power supply
cord is disconnected from the AC outlet.
Gas Supply To Range
2. To convert the surface burners for use
with L.P. gas:
a)Remove the grates and burner caps.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
Gas Supply Line
Gas Valve Handle To “Shutoff” Position
Grate
Burner Cap