22
SYNTH TABLES
Roland Juno-106 / MKS-7
Cable requirements
The Roland Juno-106 uses a standard MIDI cable
Equivalent controls
The Roland Juno-106 did not have a dedicated controller available.
Roland
©
Juno-106 Controls
Osc 1 Range (1) 16', 8', 4' LFO Wave (26) Not Used (sine only)
Osc 1 Wave (2) Sawtooth / Pulse Only LFO Delay (27) Active
Osc 1 PW (3) Not Used LFO Speed (28) Active
Osc 1 Tune (4) Not Used Chorus/FX Rate (29) Not Used
Osc 1 LFO Mod (5) Active Chorus/FX Mode (30) Chorus Off, Mode 1, Mode2
Osc 1 ENV Mod (6) Not Used HPF (31) Active
Osc 1 Mode (7) PWM Source Select - LFO or Manual LPF Cutoff (32) Active
Osc 1 PWM (8) Active LPF Resonance (33) Active
Osc 1 Level (9) Not Used Filter LFO Modulation
(34)
Active
Noise Level (10) Active Filter ENV Modulation
(35)
Active
Osc 2 Range (15) Not Used Filter Key Follow (36) Active
Osc 2 Wave (16) Not Used Filter ADSR (37-40) Not Used
Osc 2 PW (17) Not Used Filter Mode (41) Envelope Polarity
Osc 2 Tune (18) Not Used VCA ADSR (42-45) Active
Osc 2 Fine Tune (19) Not Used VCA Mode (46) Envelope, Gate
Osc 2 LFO Mod (20) Not Used VCA Level (47) Active
Osc 2 ENV Mod (21) Not Used
Osc 2 Mode (22) Not Used
Osc 2 PWM (23) Not Used
Osc 2 XMod (24) Not Used
Osc 2 Level (25) Sub Osc Level
Roland Juno 106 Notes
The Juno 106 synthesizers have one oscillator which is divided by two to give a sub oscillator for each of the six
voices. The oscillator design is a digital system and the filter and the VCA is the custom Roland chip the 80017a
filter hybrid for each of the six voices.
The oscillator 1 Wave switch (1) is used to step though the possible wave types. These are Sawtooth and Pulse
or combination only.
There is no separate EG controls for the filter and the VCA EG controls (42-45) are used for Oscillator, Filter and
VCA modulation.
Note: Because the switch settings are combined into two commands changing one switch will cause the others
in the same command to be sent also with whatever settings are on the Patch Editor. This is unavoidable due to
the way the Juno-106 is controlled.
Switch combinations are
1) Chorus, Wave and Range selections.
2) HP Filter, VCA Env, Envelope Polarity & PWM selections.
The MKS-7 can be controlled using the Juno-106 Patch
www.kiwitechnics.com Patch Editor v6.0