SECTION 9
HYDRAULIC SYSTEM
Jan 2003
p. 9-6
80073463
9.3.3 Motor/ Pump Coupling
1. Remove access cover on item (5). See Section 12 “Motor Pump
Assembly” for soft coupling part number information.
2. Remove pump assembly items (2, 3, 4 etc).
NOTE:
Pump shaft must be moved backwards approximately 1.00 inches.
Support pump assembly with wood blocks, remove mount screws, attempt to
move pump assembly without removing attaching hoses.
3. Remove soft coupling (8). Inspect for damage to metal coupling halves
(6) and (7).
4. Install replacement soft coupling (8).
5. Slide pump assembly into soft coupling, install mounting bolts re-
attaching main pump (4) to housing (5).
6. Inspect soft coupling for proper fit, then replace access plate on
housing (5).