SECTION 8
ELECTRICAL SYSTEM
p. 8-4
05148408
8.1.2 Control Circuits and Logic
The operator controls the waterjet pump primarily through the digital
display panel. The digital interface (display) communicates with the PLC
controller located inside the electrical enclosure.
In order to avoid costly damage to the pump, automatic shutdown logic
and diagnostic messages are displayed to the operator as to the cause of
the impending shutdown. The inputs that trigger automatic shutdown
are:
Motor Overload
Motor Feedback Failure
Oil Level Low
Oil Temp High
Low Booster Pressure
Low Inlet Water Pressure
Long Idle Time Shutdown
Booster Temp High
Left Overstroke Shutdown
Right Overstroke Shutdown
Topworks Overstroke Shutdown
For more information on these conditions and recovery procedures, refer
to Section 3, Operation, of this manual.
The functions listed below are available by connecting to terminal blocks
in the starter/control enclosure. An optional 37-pin circular connection
mounted in the side of electrical enclosure is available.
Start
Stop
Emergency Stop (E-Stop)
Pump RUN indicator light
Pump malfunction light
Remote 2-pressure
Proportional Pressure (optional)