SECTION 7
HIGH PRESSURE WATER
May 2003
p. 7-19
49831951
7.3.3 Sealing Head
The sealing head should be inspected for scratches and wear on two
surfaces:
HP cone ring seal contact surface
Inlet HP check valve poppet contact surface
1. Polish the cone ring 45 degree surface to achieve a smooth finish.
Grooves or machine tool marks should be barely discernable by
fingernail test.
2. Inspect the inlet poppet sealing surface of the sealing head for pits,
scratches, or jetting erosion. Refinishing the seal head inlet poppet face
is mandatory when rebuilding the sealing head. Using a piece of plate
glass (not window glass) on a sturdy table, place a piece of 400 grit
wet/dry sandpaper atop the plate of glass which provides the absolutely
flat surface necessary for the polishing process. Using even, deliberate
strokes, polish the sealing head until smooth. Rotate the head about 10-
15 degrees every stroke. Be careful not to tilt or tip the head while
polishing it as to not scrape the part.
3. When the sealing head is flat and smooth, perform a final polish with
600 grit wet/dry sandpaper. A mirror finish is required. Ingersoll-Rand
offers a refinishing service.