EasyManuals Logo

KMT SL-IV PLUS Series User Manual

Default Icon
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #121 background imageLoading...
Page #121 background image
SECTION 11
SPECIFICATIONS
Jan 2003
p. 11-5
80073455
To predict the tendency of scale formation, the Langelier's saturation index can
be used as a guide.
Saturation Index = pH-pHs where pHs is calculated at saturation with calcium
carbonate.
A positive index indicates a tendency to deposit calcium carbonate, the higher the
positive value, the higher the scale formation. A zero index corresponds to water
that is in equilibrium with respect to calcium carbonate.
11.5 Orifice Support Capacity
The SL-IV Waterjet Pump supplies high pressure (HP) water up to 4,100 bar
(60,000 psi). The following table shows size, ratings, and maximum quantity of
orifices that can be supported.
Rated power
kW(hp)
Pressure
Bar (Psi)
Flow
lpm (gpm)
Qty
Orifice Diameter
mm (inch)
1 0.36 (0.014)
1 0.33 (0.013)
2 0.28 (0.011)
45 (60) 4,100 (60,000) 3.87 (1.023)
2 0.25 (0.010)
1 0.38 (0.015)
1 0.36 (0.014)
1 0.33 (0.013)
1 0.30 (0.012)
2 0.28 (0.011)
45 (60) 3,800 (55,000) 4.43 (1.17)
2 0.25 (0.010)