EasyManuals Logo

KMT SL-IV PLUS Series User Manual

Default Icon
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #92 background imageLoading...
Page #92 background image
SECTION 7
HIGH PRESSURE WATER
May 2003
p. 7-29
49831951
7.4 HP Dump Valve
The dump valve assembly includes a normally open HP water valve, plus
a solenoid operated air valve for the air actuator on the dump valve.
Replacement parts for the HP valve are provided in the Parts Lists
(Section 12, see Figure 12-7, “Bulkhead Piping Assy”).
7.5 HP Attenuator
There is no servicing of the HP attenuator at the customer level. The
seals in the HP attenuator are tested at Ingersoll-Rand to high pressure
in excess of operating pressure making disassembly difficult. In the
event of a HP water leak of a HP attenuator, the attenuator should be
replaced. The defective attenuator should be returned to KMT Waterjet
for replacement or servicing.