In case of 《Double Strip》 is setting, 《Diameter》・《Brade Move Back》 can be set for
outside insulation. (reference P.19)
For this screen, the front core wire diameter is 3.1mm, blade move back is 1.6mm,
outside insulation diameter is 4mm, and blade move back is 1mm.
⑨《Double Strip》: It sets for using double strip processing.When double stripping is setting.
《Basics》 screen changes to 《Double Strip》.(See P.18)
Caution:Short Mode and Double Strip are application of Semi-strip processing.
When adherence of core wire and insulation is strong, processing may not
be performed just like setting. Please change the settings flexibly based on
the processed wire materials.
⑩It is set when half stripping processing of the core wire which is doubly insulated is
performed at sheath strip. 《Basics》 screen changed to 《Sheath Strip》. (See P.19)
⑪It is set when half stripping processing of the outside insulation of the wire which is doubly
insulated at sheath strip of the doubly insulated wire. 《Basics》 screen changes to the 《Sheath
Strip》.(See P.20)
⑫《Initialization》: It initializes screen dates. If the intended process can't be performed or
changed settings are unsure, it may be faster to initialize and re-enter the
settings.
・All of the 《Motion》 screen and 《Basics》 data are initialized. Optional devices settings
will also be initialized and unconnected states.
・All of the 《Speed》 on the 《Machine Adj》 screen will be “ 7 “.
・《Total Length Correction》, 《Total Processed Number》, and 《Blade Origin》 on the
《Machine Adj》 screen are not initialized.