EasyManuals Logo

Kohler KDI 2504 M-MP User Manual

Kohler KDI 2504 M-MP
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
6
31
_00
Fig. 6.14
Fig. 6.12
Fig. 6.13
A
A
C
C
D
D
P
F
F
F
G
G
E
E
B
B
H
Fig. 6.15
ED0053031100
INFORMATION ABOUT REPLACEMENTS
EN
6.6 Alternator belt replacement
1 -
Loosen capscrews A and remove guard B.
2 -
Loosen hollow stud C and capscrew D.
3 -
Remove the belt F.
4 -
Perform the operations from point 2 to 6 of Par. 6.7.
5 -
Insert the new belt F on
pulleys G.
6 -
Move alternator E in
the direction of arrow
H, tighten capscrew D
followed by hollow stud
C (tightening torque at 40
Nm).
7 -
Check the tension of belt
F with a Clavis-type of
instrument, positioning it
in point P (the value must
be 392 N).
8 -
Secure guard B with capscrews A (tightening torque at 5
Nm).