7
35
_00
Tab. 7.3
E
D
F
ED0053031100
INFORMATION ABOUT FAILURES
EN
7.2 Error signals on the control panel
Tab. 7.3 shows the errors that can be generated on the control
panel.
POS. DESCRIPTION
Engine oil pressure low
High coolant temperature
Disabled alternator (with engine rpm <
850 rpm)
Maintenance service (*1)
Insufcient battery voltage (ashing
display with battery < 9 V)
Besides visual signals, acoustic errors are also transmitted
from the panel.
Any errors disappear automatically once the anomaly has
been solved.
(*1) - A maintenance service does not automatically carry out
a reset; it must be reset manually, as follows:
1 - Press the E push button until the maintenance service page
(Service h) is displayed on the screen D.
2 - Simultaneously press push buttons E and F for 10 secs.
for screen D to reset the hours until the next maintenance.