EasyManuals Logo

Kohler KDI 2504 M-MP User Manual

Kohler KDI 2504 M-MP
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
6
29
_00
A
A
B
Fig. 6.4
Fig. 6.5
B
A
C
F
D
Fig. 6.6
ED0053031100
INFORMATION ABOUT REPLACEMENTS
EN
Warning
Oil filter cartridge replacement (Par. 6.2) and fuel filter replacement (Par. 6.3)
In case of low use replace it 12 months.
For disposal of oil filter cartridge and fuel filter refer
to Par. 6.9 DISPOSAL and SCRAPPING.
6.2 Oil lter cartridge replacement
1 -
Unscrew the oil filter A with appropriate wrench.
2 - Assembly and tighten the new oil filter cartridge
A tightening it with torque wrench B (torque to
15 Nm).
6.3 Fuel lter cartridge replacement
1 -
Procure a suitable container to collect the fuel.
2 - Loosen and remove cartridge A.
3 - Lubricate the gasket C of the new cartridge.
Tighten the new cartridge A onto support B (tighten
manually).
Important
Do not fill the new cartridge A with fuel.
4 - Turn the key on the control panel to the ON position.
The electric pump D sends fuel to the filter B and then the
injection pump.
5 - Loosen the air bleeding screw F on fuel filter bracket B.
The air inside the circuit and the filter will begin to escape
from the screw F.
6 - Tighten the bleeding screw F (tightening torque of 1.5 Nm)
when the fuel begins to flow.

Table of Contents