- 23 - - 23 -
KDW 2204/TKDW 2204
CHARACTERISTICS POWER, TORQUE AND SPECIFIC FUEL CONSUMPTION CURVES
Technical information
Workshop Manual KDW 1603_2204_2204/T _ cod. ED0053029180 - 1° ed_rev. 00
N (80/1269/CEE - ISO 1585) AUTOMOTIVE RATING: intermittentoperationwithvariablespeedandvariableload.
NB (ISO 3046 - 1 IFN) RATING WITH NO OVERLOAD CAPABILITY:Continuouslightdutyoperationwithconstandspeedand
variableload.
NA (ISO 3046 - 1 ICXN) CONTINUOUS RATING WITH OVERLOAD CAPABILITY: continuous heavy duty with constant
speedandconstantload.
MN Torque curve (N curve) - MB (NB curve) - MA (NA curve).
C: Specicfuelconsumptioncurve(NB curve)
Max.powertoleranceis5%.
Powerdecreasesbyapproximately1%every100maltitudeandby2%every5°Cabove25°C.
Enginepowercanbeinuencedbythetypeofcouplingusedwiththecoolingfan.
Important
Non-approval by Kohler for any modications releases the company from any damages incurred by the engine.
Note: ConsultKOHLERforpower,torquecurvesandspecicconsumptionsatratesdifferingfromthosegivenabove.